The 975XL2 Reduced Pressure Principle Assembly is used in high health hazard, potable water applications for protection from both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, bronze body design provides separate access to each check valve and the relief valve to reduce labor costs and repair time. Its short lay length eases replacement costs and installation time. The 975XL2 includes all the necessary components for managing your system, and is the simplest, best, and most reliable backflow preventer in the market today.

  • Short lay length eases replacement and repair time
  • Wye pattern design provides separate access to checks and relief valve for reduced labor costs
  • Trusted and recognized favorite by installers worldwide
  • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
  • Meets the requirements of NSF/ANSI 61
  • ASSE® Listed, cUPC® Listed, CSA® Certified, AWWA Compliant, Safe Drinking Water Act Compliant

Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. The assembly can be configured with a relief valve sensor that detects and signals excessive water discharge that, if left undetected, may cause property damage from flooding.

Standards Compliance

• ASSE® Listed 1013

• cUPC® Listed

• CSA® Certified B64.4

• AWWA Compliant C511

• Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California

• Meets the requirements of NSF/ANSI/CAN 61 and 372* *(LESS THAN 0.25% WEIGHTED AVERAGE LEAD CONTENT)

• UL® Classified (less shut-off valves or with OS&Y valves)

• C-UL® Classified

Materials

Main valve body  Low Lead Cast Bronze ASTM B 584

Access covers  Low Lead Cast Bronze ASTM B 584

Fasteners  Stainless Steel, 300 Series Elastomers  Silicone   Buna Nitrile

Polymers  Noryl™

Springs   Stainless Steel, 300 series

Ball valve handles Stainless Steel

Maximum working water pressure  175 PSI

Maximum working water temperature 180°F

Hydrostatic test pressure   350 PSI

End connections Threaded   ANSI B1.20.1

 

 